PRODUCT PROPERTIES:
- One component, Hybrid Polyurethane base.
- Low viscosity, easy to apply.
- Low solvent content.
- Very good bonding on various surfaces.
- High solid content creates a durable and seamless waterproof membrane.
- Excellent flexibility and crack-bridging performance (from 3 to 5mm).
- Resistant to elevated temperatures, frost and de-icing salts.
- Good chemical resistance.
- Optimized workability for application by roller, squeegee, brush and airless spraying on horizontal and inclined surfaces.
AREAS OF APPLICATION:
- Waterproofing for roofs, planting areas, balconies, loggias, drying yards, sewage tanks, etc.
- Waterproofing for bridge deck, basement, foundation,…
PRODUCT CHARACTERISTICS:
| Form | Liquid |
| Color | Black |
| Storage | Store in dry, cool, covered and ventilated place. |
| Life time | 12 months from manufacture date stored in original unopened packs. |
| Packing | 22 kg or 28 kg steel pail |
APPLICATION NOTES:
- Substrate preparation:
– MC-Proof PU 920 can be applied on all mineral substrates, metals, plastics and even wood.
– All substrates to be coated must be sound, clean and free from all loose particles, dust, oil and any other contaminants (e.g. release agent, cement residue).
– Surface tensile strength must be > 1.5N/mm². The moisture content of the substrate must not exceed 10%.
– Holes and indentations > 5mm deep must be filled with a suitable specialized repair mortar (e.g. Nafufill KM 103).
– At the junction of the floor and the wall, it must be plastered to create a curvature to prevent cracking of the waterproofing membrane.
– Before applying MC-Proof PU 920, joints and cracks must be prepared. Cracks with water leakage can be repaired with specialized products of MC-BIFI (eg MC-Injekt 2188, MC-Injekt 2300,…).
- Primer: Primer is basically not required, however, for maximum adhesion efficiency or requirements with higher than normal adhesion, it is recommended to use Primer with MC-Proof PU 920 mix with 10% thinner.
- Application:
– MC-Proof PU 920 is a ready-to-use liquid PU based, and it needs to be stirred to homogenize before use.
– A slow-speed mechanical stirrer should be used to avoid the entrainment of air into the mixture during stirring.
– Apply MC-Proof PU 920 by roller, brush or spray directly onto the prepared surface.
- The consumption is 1.5 kg/m² corresponding to the waterproof layer thickness of 1.0 mm. To achieve the recommended 2.0 mm dried layer thickness, 2 coats should be applied and the waiting time between 2 applications should be at least 6 hours. This waiting time depends on the temperature and other climatic conditions at the site.
– After construction, the protective mortar layer should be rolled onto the waterproof layer, to ensure the long-term durability of the waterproof layer.
- Curing: After application, MC-Proof PU 920 needs to be protected until the waterproofing layer meets the final specifications (e.g. traffic, rain, humidity >90% RH, etc.)
- Cleaning: Cleaning tools and equipment with MC-Thinner after use. Hard materials can only be removed by mechanical agents.
- Safety information: MC-Proof PU 920 contains no harmful substances that require labeling. Very safe under normal working conditions such as wearing gloves and goggles, etc. MC-Proof PU 920 causes mild skin sensitization upon direct contact.
TECHNICAL DATAS:
| Characteristic | Unit | Value | Comments |
| Density | g/cm³ | 1.48 | ASTM D1475-13 |
| Viscosity | cps | ~5.000 | ASTM D2196-15 |
| Hardness Shore A | 50 ± 5 | ASTM D2240 | |
| Solid content | % | > 80 | ASTM D2369-10 |
| Elongation to break | % | > 600 | ASTM D412-16 |
| Tensile strength | Mpa | ≥ 2 | ASTM D412-16 |
| Adhesive strength to concrete | Mpa | ≥ 1 | ASTM D7234 |
| Rain and foot traffic resistance | Hour | > 6 | |
| Watertightness test time | Hour | ~ 36 | |
| Consumption | kg/m/m | 1.5 | |
| Application conditions | °C
% % °C |
≥ 6 ≤ 40
≤ 85 ≤ 10 3 |
Air and substrate temperature
Relative humidity Substrate residual moisture Above dew point |
*All technical data are based on laboratory tests at 23°C ±2 and 60% RH and may vary in practical application. To determine the individual technical suitability, preliminary suitability tests should be carried out under the application conditions.